NAME
CSSM_HRS_Enroll, HRS_Enroll — Captures biometric data for the purpose of enrollment
SYNOPSIS
#include <hrs.h>
API
CSSM_RETURN CSSMAPI CSSM_HRS_Enroll (CSSM_HRS_HANDLE ModuleHandle, CSSM_HRS_BIR_PURPOSE Purpose, const CSSM_HRS_INPUT_BIR *StoredTemplate, CSSM_HRS_BIR_HANDLE_PTR NewTemplate, const CSSM_DATA *Payload, sint32 Timeout CSSM_HRS_BIR_HANDLE_PTR AuditData);
|
SPI
CSSM_RETURN CSSMHRI HRS_Enroll (CSSM_HRS_HANDLE ModuleHandle, CSSM_HRS_BIR_PURPOSE Purpose, const CSSM_HRS_INPUT_BIR *StoredTemplate, CSSM_HRS_BIR_HANDLE_PTR NewTemplate, const CSSM_DATA *Payload, sint32 Timeout CSSM_HRS_BIR_HANDLE_PTR AuditData);
|
LIBRARY
HRS Extensible Module Manager (cdsa$inhrsemm_shr.exe)
PARAMETERS
The parameter definitions are the same for the API and the
SPI.
ModuleHandle (input) | | The handle of the attached HRS service provider. |
Purpose (input) | | A value indicating the desired
purpose of Enrollment. |
StoredTemplate (input/optional) |
| | Optionally, the BIR to be
adapted, or its key in a database, or its handle. |
NewTemplate (output) | | A handle to a newly created
template that is derived from the new raw samples and (optionally)
the StoredTemplate. |
Payload (input/optional) | | A pointer to data that will
be wrapped inside the newly created template. This parameter is
ignored, if NULL. |
Timeout (input) | | An integer specifying the
timeout value (in milliseconds) for the operation. If this timeout
is reached, the function returns an error, and no results. This
value can be any positive number. A ?1 value
means the BSP’s default timeout value will be used. |
AuditData (output/optional) | | A handle to a BIR containing
biometric audit data. This data may be used to provide human-identifiable
data of the person at the device. If the pointer is NULL on input,
no audit data is collected. Not all HRS service providers support
the collection of audit data. An HRS service provider may return
a handle value of CSSM_HRS_UNSUPPORTED_BIR_HANDLE to indicate
AuditData is not supported, or a value
of CSSM_HRS_INVALID_BIR_HANDLE to indicate
that no audit data is available. |
DESCRIPTION
This function captures biometric data from the attached device
for the purpose of creating a ProcessedBIR for the purpose of enrollment.
The Enroll function may be split between client and server if a
streaming callback has been set. Either the client or the server
can initiate the operation.
RETURN
VALUE
A CSSM_RETURN value indicating success
or specifying a particular error condition. The value CSSM_OK indicates
success. All other values represent an error condition.
ERRORS
Errors are described in the CDSA Technical Standard.
CSSMERR_CSSM_NOT_INITIALIZED
CSSMERR_CSSM_FUNCTION_FAILED
CSSMERR_CSSM_FUNCTION_NOT_IMPLEMENTED
CSSMERR_CSSM_FUNCTION_INTEGRITY_FAIL
CSSMERR_HRS_PURPOSE_NOT_SUPPORTED
CSSMERR_HRS_RECORD_NOT_FOUND
CSSMERR_HRS_TIMEOUT_EXPIRED
CSSMERR_HRS_TOO_MANY_HANDLES
CSSMERR_HRS_UNABLE_TO_CAPTURE
CSSMERR_HRS_UNABLE_TO_WRAP_PAYLOAD