HP Instant Capacity User's Guide for versions 8.x > Chapter 8 Troubleshooting
Troubleshooting the Instant Capacity Software
In the event the Instant Capacity software is not functioning,
perform the following steps: Verify that the Instant Capacity software is installed and not corrupted. On HP-UX systems, this can be done by entering the following command: /usr/sbin/swverify B9073BA You should see Verification succeeded. in the output of the swverify command. On OpenVMS systems, enter the following commands to verify that the Instant Capacity and WBEM software are installed and configured: $ @sys$manager:ICAP$CLI_UTILS.COM CONFIG_CHECK $ show log ICAP$CONFIGURED “ICAP$CONFIGURED” = “TRUE” (LNM$JOB_nnnnnnnn) $ pipe product show hist | search sys$pipe WBEMCIM HP I64VMS WBEMCIM A2.0-A051013F Full LP Install Val 16-APR-2006 (HP-UX) If there is an error
from the swverify command in Step 1 (above) then reinstall the Instant Capacity software.
Refer to “Installing
Instant Capacity Software” for
details. (OpenVMS) If the Instant Capacity software
is not configured, configure it using SYS$MANAGER:ICAP$CONFIGURE.COM . If the WBEMCIM software is not installed, install it using the PRODUCT INSTALL utility. Verify that the status of your Instant Capacity system/partition is correct by entering the following command: (HP-UX) /usr/sbin/icapstatus (OpenVMS) $ICAP SHOW STATUS
You should see something similar to “B.08.00” as the Instant Capacity software version. If you do not have a version 8 installed, install the Instant Capacity 8.x software. If there is a discrepancy between the number of reported components with or without usage rights and your Instant Capacity contract, send an e-mail to the Instant Capacity administrator at icap_admin@hp.com that explains the discrepancy. Ensure that the required processes for Instant Capacity are running. On HP-UX systems, verify that the icapd daemon is running on the system/partition by entering the following command: /usr/bin/ps -e | grep icapd You should see the icapd daemon running on the partition. If it is not running, check the system log file (syslog) for icapd error messages and take the appropriate action. On OpenVMS systems, verify that the ICAP_SERVER and WBEM CIMSERVER processes are running: $ pipe show sys | search sys$pipe ICAP_SERVER %SEARCH-I-NOMATCHES, no strings matched $ pipe show sys | search sys$pipe CIMSERVER 202046D CIMSERVER HIB 10 8335702 0 00:22:46.98 75250 77655 M You should see a line of output listing the process information. In the above example, the CIMSERVER process is running and the ICAP_SERVER process is not running. (HP-UX) Ensure that the kernel
driver diag2 is built into the kernel. (HP-UX) Ensure that the NParProvider
bundle is installed. Ensure that the required WBEM
provider modules are installed and running. On
HP-UX systems, the WBEM B8465BA bundle
(version A.01.05 or higher) must be installed. On
OpenVMS systems, verify the WBEM installation using the following commands:
$ cimprovider :== $WBEM_OPT:[wbem.bin]cimprovider $ pipe cimprovider -l | search sys$pipe - “HP_NParProviderModule”,”HP_iCAPProviderModule”, ”HP_iCODProviderModule” HP_NParProviderModule HP_iCAPProviderModule HP_iCODProviderModule All three of the provider modules
listed above must be loaded. (HP-UX) Make sure par commands
such as parstatus are working. For failures in virtual partitions, check
the vPar commands such as vparstatus. Check the Instant Capacity log
file and syslog file for any error messages. On HP-UX systems, these
files are /var/adm/icap.log and /var/adm/syslog/syslog.log. On OpenVMS systems, these files are sys$manager:icap.log and sys$manager:operator.log.
Additional Troubleshooting Steps for E-mail ConnectivityIf you are utilizing asset reporting, perform the following
additional troubleshooting steps to ensure that HP is able to receive
an e-mail message from the Instant Capacity software: Execute the command: /usr/sbin/icapnotify <reply_address> Where reply_address is the e-mail address where you desire HP to send a confirmation message. Verify that HP replies with a
confirmation message, via e-mail, to the reply address specified
in Step 1
If you do not receive the confirmation e-mail message in Step
2 from HP then your partition is unable to send e-mail over the
internet to the hp.com domain. See “Diagnosing
E-mail Configuration” for details on troubleshooting
your e-mail configuration.
|